Philips LED Panel Coreline SM136V 31W 3100lm/3700lm/4300lm - 840 Cool White | 120x20cm - UGR <25 - Selectable Wattage - Emergency 3H - W3
€465.74
€377.93
excl. Tax
incl. Tax
+
€0.72
Ecotax
Expected shipping before 8 November
i
This product is on stock, we will do our utmost effort to ship the products today.
This product will be in stock on the mentioned date. We will do our utmost effort to ship the products on the date they are on stock.
This product is currently not in stock. We will do our utmost effort to ship the products to you as soon as possible. Please take into account that the delivery time might be longer.
This product is currently not in stock. Do you want to buy one or more items of this product? Then we will place an order directly with our supplier! We will do our utmost effort to ship the products to you as soon as possible. Please take into account that the delivery time might be longer.
Want to order larger quantities?
Specifications
General Information
SKU | 241077 | |
---|---|---|
EAN | 8718699975661 | |
Manufacturer Name | SM136V 31S_37S_43S/840PSUW20L120OCELB3W3 | |
i
Our all-in warranty is fully included in the product price and covers both hidden defects and technical defects of the product that occurred before delivery. The warranty period differs per product and ranges from 1 year to a maximum of 5 years.
|
Any Lamp all-in warranty | 5 Years |
Average Lifetime (h) | 50000 |
Technical Information
i
The technology indicates the operating base of a light source. The most well-known and energy-efficient example is LED. Other techniques include Halogen, gas discharge, TL (fluorescent) and the light bulb.
|
Technology | LED Integrated |
---|---|---|
i
This indicates which wattage of your old/conventional lighting is replaced by this LED product.
|
Replaces (Watt) | 2x36 |
i
The wattage indicates how much energy a light source consumes. With LED lighting, the wattage is considerably lower than with conventional lighting. LED lamps with a higher wattage generally also have a higher light intensity (number of lumens).
|
Wattage | 31 |
i
Lighting with a voltage of 220-240 Volt can be connected directly to the mains. Lighting with a different mains voltage (12 Volt and 24 Volt) requires an (electronic) transformer.
|
Voltage (V) | 220-240 |
i
When you dim lights, the full power does not have to be used. You therefore save extra on energy costs. Dimmable lamps can also be used to create an extra cosy atmosphere. Keep in mind that you need a LED dimmer to dim LED lights.
|
Dimmable | Not Dimmable |
i
|
Colour temperature (Kelvin) | 4000K - Cool White |
i
The colour code is a combination of colour rendering (CRI) and light colour (Kelvin). The first number indicates the colour rendering (1 = very poor colour rendering, 9 = maximum colour fastness). The second and third number contains the light colour. Example: the colour code 830 consists of good colour rendering (8) and warm white light (3000K).
|
Colour Code | 840 Cool White |
i
Colour rendering is also known as Colour Rendering Index (CRI) and indicates the extent to which a light source reproduces colours, compared to the actual colours in daylight. Products with a good (80-89 Ra) or excellent (90-99 Ra) colour rendering show minimal deviations in the colour spectrum.
|
Colour Rendering (Ra) | 80-89 |
i
A beam angle indicates the angle of the light beam coming from a light source. The smaller the radiation angle in degrees (D), the narrower the beam angle.
|
Beam Angle (degree) | 100 |
i
The number of lumens (lm) is the light output of a light source. The higher the number of lumens, the more light the light source emits. The wattage and the number of lumens are not connected to each other. An LED lamp with a low wattage can have a higher number of lumens than a conventional lamp with a high wattage.
|
Luminous Flux (Lumen) | 4300 |
i
The Luminous Efficacy (lm/W) indicates how efficiently a light source uses energy. We divide the number of lumens by the wattage. The higher the number, the more efficient a product is in terms of energy consumption. LED lighting has a considerably higher lumen/Watt ratio than conventional lighting.
|
Lumen per watt | 140 |
i
The IP value indicates the degree of protection against the ingress of moisture and dust. The 1st digit (0 = not protected until 6 = completely dustproof) indicates the protection against dust. The 2nd digit (0 = not protected until 8 = protected against immersion) indicates the protection against water. Products with an IP44 rating are splashproof and products with an IP65 rating or higher are (completely) dustproof and waterproof.
|
IP-Rating | IP20/IP44 |
i
The impact protection value (IK) stands for impact resistance and protection against vandalism. This is expressed in combination with 2 digits (IK00 - IK10). Products with IK00 are not protected against resistance. Products with IK10 offer resistance to shocks of 20 Joule and are also vandal-proof.
|
Impact Protection (IK) | IK03 - 0.35 joule |
Fixture Connection | Cable, 3-pole | |
Driver Included | Yes | |
i
The power factor indicates how efficiently a luminaire uses electricity. The rule is: the higher the power factor, the more efficient the power consumption. A product with a high power factor (0.85 - 0.95) is also the safest. This is because the amount of unnecessary power consumption (blind current) is very limited.
|
Power factor | >0.90 |
i
This filter allows you to refine your search by selecting specific types of light sources. Choose from options such as LED bulbs, LED tubes, or LED spots to find the perfect lighting solution for your needs.
|
Product Type Category | LED Panel |
Fixture Information
EOC8 | 97566100 | |
---|---|---|
Mounting Method | Surface | |
i
The Unified Glare Rating (UGR) indicates the extent to which the light of a product is blinding. This value differs per application and must comply with European standards (EN 12464-1). A low UGR value stands for a low glare factor. For offices and schools lighting with a UGR<19 value is mandatory and for public areas UGR<22.
|
Unified Glare Rating | < 25 |
Optical Cover | PC (Polycarbonate) | |
Operating Temperature | -10 to +40 | |
i
Lighting with a built-in emergency lighting unit (battery) continues to burn for a certain time if the power fails.
|
Emergency Lighting | 3H Emergency Light |
Colour of the Fixture | White | |
Housing | Steel | |
Colour of material | White |
Dimensions
i
The most common sizes of LED panels are 60x60cm (square) and 30x120cm (rectangular). These are standard sizes for almost all suspended ceilings. There are also various other dimensions available, such as 20x120cm or 15x150cm.
|
LED panel size | 120x20cm |
---|---|---|
i
It may happen that the length of this product differs from your old lighting fixture. As a result, the product does not fit in your current fixture or in the relevant place.
|
Length (mm) | 1200 |
Width (mm) | 200 | |
Height (mm) | 68.5 |